Brand Name: LYTTE
Model Number: LTMLH(R)
Place of Origin: Shandong, China (Mainland)
high efficiency flooded ground source heat pump
LUTE Heat pump central air conditioning system
A. LUTE brand---china famous brand
B. Adopt import advanced American technology
C. Using world famous accessories as compressor etc
D. Designed by ourselves, own tens of design patents
E. Most energy saving and lowest running charge
F. Adopting environmental protection refrigerant as R134A, R22, R407C etc
G. Advocacy the government Energy-saving and emission-reduction policy
H. Apply for kinds of buildings for cooling, heating and making hot water
I.Most Advanced Testing and Inspection System and We Promise that Each Unit will Be Tested Over 48hours to Be Proved Qualified
J. We Solemn Promise Quick After Service and Very Priced with Highest Quantity
We sincerily invite you to come to visit us and cooperate in the oversea markets.
high efficiency flooded ground source heat pump(Model LTMLH(R))
1.High efficient flooded ground source heat pump
2.Cooling Capacity: 247-3600KW
3.Heating Capacity: 260-3805KW
4.Product Advantages:
A.Compared with the dry evaporator, adopting flooded evaporator COP increased by 1.5
B.Heat&Cool resource come from groundwater, surface water (river, lakes, sea) and soil etc.
C.At the end of the air conditioner, radiant floor, radiator, fan coil units and other end form to provide heating&cooling, also prepare free water as per request
D.A 5:6 tooth gear design in the world famous twin-screw compressor, small vibration, low failure rate, advanced energy control method can achieve a paragraph or unwarranted energy regulation
E.Injection compression, noise seal
F.Control device using the world famous, PID regulation; Large-screen color touch screen
G. Large range of application: Hotels, restaurants, hospitals, office buildings, theaters, stadiums, residential quarters, textile, food, medicine, metallurgy, chemicals and boiler works etc
high efficiency flooded ground source heat pump(Model LTMLH(R))
Notes:
1.Unit cooling capacity and compressor power consumption Calibration conditions(cooling conditions):
Chilled water inlet temperature 12°C, outlet water temperature 7 °C
Cooling water inlet temperature 18 °C, outlet water temperature is 29 °C
2. Unit heating capacity and compressor power consumption calibration conditions(heating conditions):
Hot water inlet temperature 40°C, outlet water temperature 45 °C
Cooling water inlet temperature 15 °C ,outlet water temperature 7°C
3. When the cooling water temperature range is different from the calibrate mode, press the design performance curves to select their unit refrigeration / heat and power consumption.